Cyber Suite LED Keypad Instalační manuál Strana 1

Procházejte online nebo si stáhněte Instalační manuál pro Numerické klávesnice Cyber Suite LED Keypad. Cyber Suite LED Keypad Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - CYB-KLED

CYB-KLED CyberSuite Installation Manual CYB-KLED CyberSuite LED Keypad Installation Manual

Strany 2

7 CYB-KLED CyberSuite Installation Manual Figure 9 - Slave Keypad Standard Zone Wiring PGM (Programmable Output) The CyberSuite LED Keypad uses

Strany 3 - CONTENTS

8 CYB-KLED CyberSuite Installation Manual Slave Reader Network The CyberSuite LED Keypad is capable of controlling a slave network of up to 8 prox

Strany 4 - Hardware Compatibility

9 CYB-KLED CyberSuite Installation Manual Slave Keypad Network The CyberSuite LED Keypad is capable of controlling a slave network of up to 4 ot

Strany 5 - Introduction

10 CYB-KLED CyberSuite Installation Manual Indicator Lights The CyberSuite™ LED keypad features three status indicator lights showing the condition

Strany 6 - Communication Connection

11 CYB-KLED CyberSuite Installation Manual DEVICE CONFIGURATION Device Configuration Mode Access Before the CyberSuite LED Keypad module will co

Strany 7 - Zone Input Wiring

12 CYB-KLED CyberSuite Installation Manual Device Options ([MENU] , [2]) The device options set options that relate to the mode of operation of the

Strany 8 - Fire Zone Input Wiring

13 CYB-KLED CyberSuite Installation Manual LOCAL INSTALLER LOGIN Introduction The default local installer code is [0000]. To access the local in

Strany 9 - Slave Keypad Zone Wiring

14 CYB-KLED CyberSuite Installation Manual TIMING (MENU 1) ALL 3 Digits of the timer value MUST be entered when programming a timer. This means th

Strany 10 - PGM (Programmable Output)

15 CYB-KLED CyberSuite Installation Manual Alarm/Siren ([MENU] , [1] , [3]) The siren/alarm timer is programmed from 000 to 250 minutes (Default

Strany 11 - Slave Reader Network

16 CYB-KLED CyberSuite Installation Manual Reader Pre-Alarm Timer ([MENU] , [1] , [4]) The Reader Pre-Alarm Timer is programmable from 0 to 255 seco

Strany 12 - Slave Keypad Network

CYB-KLED CyberSuite Installation Manual PUBLICATION INFORMATION First Publication Draft Document Release Only Updated fire zone information

Strany 13 - Binary Number Display

17 CYB-KLED CyberSuite Installation Manual OPTIONS (MENU 2) General Options ([MENU] , [2] , [1]) The general options set options that relate to

Strany 14 - DEVICE CONFIGURATION

18 CYB-KLED CyberSuite Installation Manual 6 Disabled no trouble beep will be generated. Option 4 - Device Power Up Disarmed 5 Enabled the system

Strany 15

19 CYB-KLED CyberSuite Installation Manual Arming Options ([MENU] , [2] , [2]) The arming options set functions that relate to the arming of the

Strany 16 - LOCAL INSTALLER LOGIN

20 CYB-KLED CyberSuite Installation Manual Reporting Options ([MENU] , [2] , [3]) The reporting options are a set of functions that relate to the re

Strany 17 - TIMING (MENU 1)

21 CYB-KLED CyberSuite Installation Manual Option 4 - Report Zone Fault 5 Enabled the system will report any zone fault trouble condition to th

Strany 18

22 CYB-KLED CyberSuite Installation Manual Panic Options ([MENU] , [2] , [4]) The panic options set functions that relate to the panic processing of

Strany 19

23 CYB-KLED CyberSuite Installation Manual Option 4 - User 8 Duress Code Enabled 5 Enabled the system will enable user code 8 to be a duress co

Strany 20 - OPTIONS (MENU 2)

24 CYB-KLED CyberSuite Installation Manual ZONES ([MENU] , [3]) Selecting a Zone To enter the Zone number selection menu, press [MENU] , [3] To

Strany 21

25 CYB-KLED CyberSuite Installation Manual Use this to set the zone type for a motion detector that is located in an entrance area

Strany 22

26 CYB-KLED CyberSuite Installation Manual Option 3 - Force Zone 5 Enabled the zone can be force armed when it is not ready to be armed. A force ar

Strany 23

CYB-KLED CyberSuite Installation Manual CONTENTS INTRODUCTION...1 Hardware Compatibility...

Strany 24

27 CYB-KLED CyberSuite Installation Manual CONTACT Contact Integrated Control Technology welcomes all feedback. Please go to our website or use

Strany 26

Unit C, 6 Ascension Place, Mairangi Bay, P.O. Box 302-340 North Harbour, Auckland, New Zealand. Phone: +64 (9) 47

Strany 27 - ([MENU] , [3])

1 CYB-KLED CyberSuite Installation Manual INTRODUCTION This document details the wiring configuration of the CyberSuite condominium control key

Strany 28 - Zone Options

2 CYB-KLED CyberSuite Installation Manual WIRING CONFIGURATION Introduction The wiring structure of the CyberSuite keypad uses an encrypted RS485 co

Strany 29

3 CYB-KLED CyberSuite Installation Manual Communication Connection Support for up to 250 keypads per condominium controller is provided, connect

Strany 30 - Contact

4 CYB-KLED CyberSuite Installation Manual Zone Input Wiring The CyberSuite LED Keypad is capable of connecting to 4 zone inputs, each zone input can

Strany 31

5 CYB-KLED CyberSuite Installation Manual Figure 6 - 4 Zone Input Duplex Mode (1K and 2K4) Fire Zone Input Wiring When wiring a zone to be a f

Strany 32

6 CYB-KLED CyberSuite Installation Manual Slave Keypad Zone Wiring With one or more slave keypads connected, extra zones beyond the normal 4 are ava