14
CYB-KLED CyberSuite Installation Manual
TIMING (MENU 1)
ALL 3 Digits of the timer value MUST be entered when
programming a timer. This means that for addresses below
100, you must enter [0] then the 2 digits of the address. For
addresses below 10, you must enter [0] , [0] followed by the
address digit.
Entry Delay Timer ([MENU] [1], [1])
The entry delay timer is programmable from 000 to 255 seconds
(Default 30 Seconds).
To program the timer value, press
[MENU] , [1] , [1] , [TIM 1], [TIM 2] , [TIM 3] , [ENTER]
Where TIM 1 ~ 3 are the timer value digits, entered using the 0 to 9
number keys.
Programming the entry delay timer to 0 will result in no entry delay
operation for any zone that has been assigned the entry delay zone
type.
Exit Delay Timer ([MENU] , [1] , [2])
The exit timer is programmable from 000 to 255 seconds (Default 30
Seconds).
To program the timer value, press
[MENU] , [1] , [2] , [TIM 1], [TIM 2] , [TIM 3] , [ENTER]
Where TIM 1 ~ 3 are the timer value digits, entered using the 0 to 9
number keys.
Programming the exit delay timer to 0 will result in no exit delay, the
system will immediately arm the CyberSuite System.